• Connect with us
  • Facebook
  • Twitter
  • YouTube
  • Linked In
For information call 561.416.1400

What Is Built Procacci Strong?


Avoiding the disruption of operations during and after a major storm is vital to the success of any business. After hurricanes Jeanne, Francis, and Charlie in 2004, Procacci Development Corporation established a new standard for Class "A" office buildings by incorporating an exceptional level of hurricane-resistance and 100% back-up power supply.

Each new Procacci Development Corporation construction projects embodies state-of-the-art hurricane-resistant design, far surpassing the level of our competitors, allowing our tenants to avoid costly interruptions and maintain enhanced protection of work product, files and property even in the event of severe hurricanes. These features dictate a commitment to quality and comprise the "Built Procacci Strong" concept.

Hurricane-Resistant

The design and construction specifications throughout the entire structure of our Class "A" office and warehouse buildings far exceed current building codes. All "Built Procacci Strong" buildings are constructed to withstand winds up to 185 miles per hour of a Category 5 hurricane. These buildings meet the current Florida Building Code for "Enhanced Hurricane Protection Area" facilities – the same specifications used for Public Hurricane Shelters. Our structural design utilizes solid concrete tilt-up wall systems, structural concrete roofs and large missile, high-impact window glazing systems that withstand the pressures generated by winds up to 185 miles per hour.

100% Power Back Up

Every "Built Procacci Strong" Class "A" office building is equipped with an emergency power system. Upon disruption of electrical service, this system seamlessly switches to power supplied by diesel generators housed in an independent hurricane-resistant building. On-site diesel tanks are sized and ready to fuel the generators for twenty days.

State-of-the-Art Equipment

All "Built Procacci Strong" buildings are constructed with innovative design features and technologically-advanced upgrades which include high-speed fiber optic internet connections, multi-zoned mechanical systems and automated building management systems that ensure maximum comfort and energy-efficiency throughout tenant suites.

Lower Occupancy Costs

Cutting-edge technology results in reduced insurance premiums, increased energy savings and lower occupancy costs for tenants without compromising on design, office amenities and a professional business environment.

Built Procacci Strong Logo

 

 

 

  


 

Built Procacci Strong
Built Procacci Strong

Built Procacci Strong
Built Procacci Strong